HD logo
Volvo-powered open diesel generator set prepared for testing
Diesel Generator Series

Volvo Diesel Generator Series

Diesel generator sets powered by Volvo engines, with supplied model-by-model technical references for project selection.

Volvo-powered open diesel generator set prepared for testing
Series Overview

Volvo Engine Range

The table presents each supplied Volvo generator set type and its corresponding engine and technical values. Project-specific electrical configuration, enclosure, and accessories are confirmed before quotation.

Power Reference
See the complete supplied specification table
Frequency
50Hz reference table; 60Hz available on request
Published Combinations
17 references
Configuration
Confirmed per quotation
Request a Quote

Explore Other Diesel Generator Brands

Compare this Volvo diesel generator series with the other published engine brand pages before requesting a project-specific selection.

Supplied Technical Reference

Generator Set Specifications

Each product record and series grouping below follows the supplied parameter table for this engine brand. The source Detail / Click column is intentionally omitted.

Values are reproduced as supplied without calculation, conversion, or reinterpretation. Final order configuration and any 60Hz requirements are confirmed during quotation.

Volvo Engine Series

17 product records
JHV-68GFTAD530GE · 68 kW / 85 kVA
Type
JHV-68GF
Output Power (kW)
68
Output Power (kVA)
85
Current (A)
122.4
Engine Model
TAD530GE
Cylinder
4
Bore × Stroke (mm)
108*130
FuelCon. (L)
4.76
Dis. (g/kW.h)
213
Dimension (mm L×W×H)
2100*700*1450
Weight (kg)
1030
JHV-88GFTAD531GE · 88 kW / 110 kVA
Type
JHV-88GF
Output Power (kW)
88
Output Power (kVA)
110
Current (A)
158.4
Engine Model
TAD531GE
Cylinder
4
Bore × Stroke (mm)
108*130
FuelCon. (L)
4.76
Dis. (g/kW.h)
214
Dimension (mm L×W×H)
2100*960*1450
Weight (kg)
1150
JHV-112GFTAD532GE · 112 kW / 140 kVA
Type
JHV-112GF
Output Power (kW)
112
Output Power (kVA)
140
Current (A)
201.6
Engine Model
TAD532GE
Cylinder
4
Bore × Stroke (mm)
108*130
FuelCon. (L)
4.76
Dis. (g/kW.h)
214
Dimension (mm L×W×H)
2200*1000*1450
Weight (kg)
1200
JHV-128GFTAD731GE · 128 kW / 160 kVA
Type
JHV-128GF
Output Power (kW)
128
Output Power (kVA)
160
Current (A)
230.4
Engine Model
TAD731GE
Cylinder
6
Bore × Stroke (mm)
108*130
FuelCon. (L)
7.15
Dis. (g/kW.h)
215
Dimension (mm L×W×H)
2500*1020*1450
Weight (kg)
1500
JHV-160GFTAD732GE · 160 kW / 200 kVA
Type
JHV-160GF
Output Power (kW)
160
Output Power (kVA)
200
Current (A)
288
Engine Model
TAD732GE
Cylinder
6
Bore × Stroke (mm)
108*130
FuelCon. (L)
7.15
Dis. (g/kW.h)
213
Dimension (mm L×W×H)
2520*1060*1530
Weight (kg)
1700
JHV-180GFTAD733GE · 180 kW / 225 kVA
Type
JHV-180GF
Output Power (kW)
180
Output Power (kVA)
225
Current (A)
324
Engine Model
TAD733GE
Cylinder
6
Bore × Stroke (mm)
108*130
FuelCon. (L)
7.15
Dis. (g/kW.h)
216
Dimension (mm L×W×H)
2550*1060*1530
Weight (kg)
1800
JHV-200GFTAD734GE · 200 kW / 250 kVA
Type
JHV-200GF
Output Power (kW)
200
Output Power (kVA)
250
Current (A)
360
Engine Model
TAD734GE
Cylinder
6
Bore × Stroke (mm)
108*130
FuelCon. (L)
7.15
Dis. (g/kW.h)
204
Dimension (mm L×W×H)
2600*1100*1530
Weight (kg)
1950
JHV-220GFTAD734GE · 220 kW / 275 kVA
Type
JHV-220GF
Output Power (kW)
220
Output Power (kVA)
275
Current (A)
396
Engine Model
TAD734GE
Cylinder
6
Bore × Stroke (mm)
108*130
FuelCon. (L)
7.15
Dis. (g/kW.h)
204
Dimension (mm L×W×H)
2600*1100*1530
Weight (kg)
1950
JHV-280GFTAD1341GE · 280 kW / 350 kVA
Type
JHV-280GF
Output Power (kW)
280
Output Power (kVA)
350
Current (A)
504
Engine Model
TAD1341GE
Cylinder
6
Bore × Stroke (mm)
131*158
FuelCon. (L)
12.78
Dis. (g/kW.h)
198
Dimension (mm L×W×H)
3100*1150*1600
Weight (kg)
2550
JHV-300GFTAD1342GE · 300 kW / 375 kVA
Type
JHV-300GF
Output Power (kW)
300
Output Power (kVA)
375
Current (A)
540
Engine Model
TAD1342GE
Cylinder
6
Bore × Stroke (mm)
131*158
FuelCon. (L)
12.78
Dis. (g/kW.h)
198
Dimension (mm L×W×H)
3100*1150*1600
Weight (kg)
2650
JHV-320GFTAD1343GE · 320 kW / 400 kVA
Type
JHV-320GF
Output Power (kW)
320
Output Power (kVA)
400
Current (A)
576
Engine Model
TAD1343GE
Cylinder
6
Bore × Stroke (mm)
131*158
FuelCon. (L)
12.78
Dis. (g/kW.h)
198
Dimension (mm L×W×H)
3100*1150*1600
Weight (kg)
2750
JHV-350GFTAD1344GE · 350 kW / 437.5 kVA
Type
JHV-350GF
Output Power (kW)
350
Output Power (kVA)
437.5
Current (A)
630
Engine Model
TAD1344GE
Cylinder
6
Bore × Stroke (mm)
131*158
FuelCon. (L)
12.78
Dis. (g/kW.h)
199
Dimension (mm L×W×H)
3100*1150*1600
Weight (kg)
3050
JHV-400GFTAD1345GE · 400 kW / 500 kVA
Type
JHV-400GF
Output Power (kW)
400
Output Power (kVA)
500
Current (A)
720
Engine Model
TAD1345GE
Cylinder
6
Bore × Stroke (mm)
131*158
FuelCon. (L)
12.78
Dis. (g/kW.h)
200
Dimension (mm L×W×H)
3200*1150*1880
Weight (kg)
3300
JHV-440GFTAD1641GE · 440 kW / 550 kVA
Type
JHV-440GF
Output Power (kW)
440
Output Power (kVA)
550
Current (A)
792
Engine Model
TAD1641GE
Cylinder
6
Bore × Stroke (mm)
144*165
FuelCon. (L)
16.12
Dis. (g/kW.h)
199
Dimension (mm L×W×H)
3200*1150*1880
Weight (kg)
3400
JHV-480GFTAD1642GE · 480 kW / 600 kVA
Type
JHV-480GF
Output Power (kW)
480
Output Power (kVA)
600
Current (A)
864
Engine Model
TAD1642GE
Cylinder
6
Bore × Stroke (mm)
144*165
FuelCon. (L)
16.12
Dis. (g/kW.h)
201
Dimension (mm L×W×H)
3300*1150*1880
Weight (kg)
3500
JHV-500GFTWD1643GE · 500 kW / 625 kVA
Type
JHV-500GF
Output Power (kW)
500
Output Power (kVA)
625
Current (A)
900
Engine Model
TWD1643GE
Cylinder
6
Bore × Stroke (mm)
144*165
FuelCon. (L)
16.12
Dis. (g/kW.h)
199
Dimension (mm L×W×H)
3350*1350*1950
Weight (kg)
3600
JHV-550GFTWD1643GE · 550 kW / 687.5 kVA
Type
JHV-550GF
Output Power (kW)
550
Output Power (kVA)
687.5
Current (A)
990
Engine Model
TWD1643GE
Cylinder
6
Bore × Stroke (mm)
144*165
FuelCon. (L)
16.12
Dis. (g/kW.h)
199
Dimension (mm L×W×H)
3400*1350*2000
Weight (kg)
3700
Order Configuration

Configuration Confirmed Per Project

Each brand page includes the required configuration sections, but unverified equipment is not listed as standard or optional.

Standard Configuration

The confirmed standard configuration list has not yet been provided. It will be published after the engine, alternator, controller, base frame, fuel system, and protection scope are verified.

Optional Configuration

Open, silent, containerized, ATS, extended fuel tank, and other order options will be listed only after their available model ranges are confirmed.

Confirm Your Volvo Generator Requirement

Send the required output, frequency, voltage, configuration, quantity, and destination. The final model and technical scope are confirmed before quotation.

Request a Quote